Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. All the electrical connections seem tight. The new pump then starts to overheat and it shuts off. Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow. I would try a couple of turns of Teflon tape on the threads to create a better seal. Thank you Thats all I can think of now. Good day everyone. Have you checked the cells voltage, amperage, or done anything other troubleshooting? Check for water under the display, or in the control box area. Changed lid gasket and plugs in basket still same issue. Hi Frank, so it ran for weeks or more on 115V, when set to accept 230V, and then it started overheating, and then ran great for about a month, but now it makes no noise at all. They dont typically make noise for long either, because at 3400 RPM, if the impeller is hitting something, it will quickly wear it down. I just replaced the flow switch and that solved one problem, but now Im only able to produce chlorine when the system is on Super Chlorinate. Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. but the digital display panel wont light up, does the propane need to be connected and turned on to make the display panel work?? The new pump was very quiet yesterday when I installed it, but this morning, I notice there is a slight medium pitch hum in the system. What should I do? For plug-in pumps, be sure the TEST button is not tripped on GFCI outlets, and that the cord is not damaged. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. We are out of ideas and no one can solve this. Ive tried setting up the vacuum with power on and power off and its no different. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. Then we hear a click and the whole display goes blank. To remedy this, simply open up your pump, and clean out any rubbish. Inside there is an o-ring that may be out of position, or need lubricant. I can turn the temperature up but not down. Hi Mike, its hard to say not knowing which control system you use. 3. loose pipe coming into pump, drawing air around fitting threads The pump may be reversible, able to accept either 115V or 230V, so the incoming voltage must match the set-up, +/- 10%. If you are getting correct voltage into the rear of the motor (120V or 240V, +/- 10%), but still the motor makes no noise at all, its likely DOA the motor at least. However, we are not able to remove the pump. I tried to prime the pump but it still doesnt kick over to cycle anything. Or buy a new motor. Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. To break the rust, you spin the shaft, or impeller. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). I was going to try one of those next, as it seems impossible to keep water in the line without it draining into the pool. Ive checked out your blog and you had very good info for audience. Hello Dave, Thanks for your insight. The pump is only one year old. There can be multiple reasons for a pool pump not priming correctly. I figure bearing, I pulled the motor off the housing and cleaned a few pine needles out of impeller but nothing else.Its only 2 years old,I take really good care of the equipment so Im surprised. I have no pressure on my filter. Override this by moving the Main Switch to Super Chlorinate. Is there a reset switch on the pump? Sandy, some hoses are clamped onto hose adapters, using a worm clamp or radiator clamp that tightens the hose to the hose adapter. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. If so, you can replace just the motor, or the entire pump. The Hayward swim profilter is making a loud noise and the top vibtrates. Check the motor diagram for the voltage wiring diagram. Ryan, is the breaker a 15-amp? Something is very loose, or missing, or clamp band threads may be damaged, please be careful people have been fatally injured by pool filter tops popping off under pressure! Replaced motor and seal on my Hayward Northstar. Its a Hayward self-priming Super Pump. Check the wiring in the back of the motor, is the cord firmly attached? MY PUMP STARTS TO PRIME THEN LOSES IT. Hi there if you are hearing no noise from the pump at all, shut off power and check the wiring connections at the pump, switch/timer, and breaker, to be sure wires are making good terminal contact. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. My Hayward mother is a 1.5 hp. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the We would like to show you a description here but the site wont allow us. Finally, it could be bad voltage, but again, it was running before just fine, so probably not that. If you have found a burnt spot or something broken on the circuit board, that is a likely power killing area. Hi Larry, valid question. The HS (High Sense (water temperature) will appear if the water sensor is reading above 105 OR if the sensor detects an increase of more than 6 with-in 60 seconds. I have backwashed the filter and the water is clear. And water around the base. I have a Hayward H250, when I turn it on the green heat light is lit and the heater seems to make a howling sound. I have replaced the Aqua Rite printed circuit board and the T-Cell-9. Or spray with shaving cream (yes! It's the same as an aquarite with a T-5 cell. If you can determine where the sound is coming from (motor or controller), that will help narrow it down. If you have an electric motor repair shop in town, they may have it in stock, or order it online. Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. If any of these readings are outside limits, replace motor. It can also just be a really dirty filter, or a clogged pump impeller. The shaft is accessed in the rear of the motor, behind the centrifugal switch. Any thoughts? Hi, my Hayward pump is about 5 years old. I bought same pump and electrician put on old twist lock cord from previous pump. It leaks from the impeler case and is noisey, so assy B is no replacement. When I try to turn the pump back on, it only hums. It was probably spouting water several feet in the air, which soaked the motor, and popped a breaker? See page 40/41 in this Hayward Troubleshooting guide. We have cleaned it 3-5 times a day and changed the d.e as well. You say the pump is connected AFTER the filter? Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. Tried to backwash. Is this normal or is there a malfunction? Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. If the wrong o-ring size was used, that could cause the problem. For more info, see page 36 of the Hayward heater owners manual. partially collapsed, or partially clogged skimmer line. When I try to start it the motor sounds like it tries to turn but doesnt and I get a pump stalled error. Thank you very much!! Did you figure this out. There is also a leak somewhere in the system because there is water on the pad. My Hayward pump is only about 3 yrs old. Maintenance. If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. There is also a faint burnt odor. My wear ring fits very loosely and it seems like impeller shaft has worn down. I believe I have a bad capacitor. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. It overheated very badly, even burning the hayward sticker off the pump itself maybe a month ago. it continues to cycle this way. What am I missing? Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. Hi Phil, hmmm, could be a breaker that is going bad they tend to wear out after 20 years or so, especially if they are used often, as a switch. The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. Maybe does a quarter of a turn. Hi Michael, sounds like the capacitor may be bad, located at 9 oclock in the motor rear, replace with exact same MFD rating. If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). Any ideas how to address this? It did not do this until we pressure washer the deck and some wood chips got into the pool. 7. Cheers! I have a Hayward Super II pump that has had a small leak between the pump housing and seal plate. A pump that simply wont start is a frustrating problem. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. Like it is getting through the shaft seal but the seal is brand new.. any thoughts? Please consider. No loose wires or insect infestation. Profile, Create a Pool Owner Hi Rodney, well the Green wire should be ground, so that eliminates one choice. It makes humming sound 1-2 times before starting. The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. Ok I switched out the capacitor and it started up and ran for about 5 second and then blew the capacitor. The original pump (assy A) smells burnt. Is the pump pot filling full of water, or does it ever catch prime fully? Click OK to extend your time for an additional 0 minutes.
our previous pump was a hayward variable. Plate appeared to be good. ), 3) the pump drain plugs (tight and Teflon tape used? If the wiring is Ok and the error persists, replace the sensor. The motor may be dead, or possibly not. At no time does the power led turn on. In such case, filter pressure is lower than normal, if the impeller is clogged. Spray off well, and soak in a 5-gal bucket, the entire Flex Tube Nest, for a number of hours, hose off again, soak for another few hours, hose off thoroughly, dunk in the pool a few times, then replace in the filter tank. Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. I dont see that code listed. I would call back the electrician, he may have fumbled this while wiring it, such a problem is rare, and could hardly be blamed on the manufacturer, but if your electrician says that its not his fault, have him put in writing on company letterhead, what the defect of the motor is which can help you in getting warranty assistance. But, you know whats not great? Do you have any suggestion for similar pump? Hi, could be that the capacitor has worn out. Any part # you can recommend ? Initially, look into the pump/strainer housing. I have tried a segmented hose and a one piece hose and when it starts to clean, it will clean for about 30 seconds and then there seems to be no water flowing into the pump. View Details Usfitnessfinder.com. Pressing on/off buttom followed only by click sound of switch. "wordCount": "1009",
The motor can be tested briefly without being bolted onto the pump. You will need a new plug and a new outlet and maybe a new pump too (? I shut the pump down the other night and it will not run. We have just replaced the seal assembly as suggested by a Hayward rep already. What could I be missing that would cause this? All the readings (salt level, amps, etc) are in the correct range. anyway I digress. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. My 4 year old pump is working well so I am not looking to switch it, but I am curious if I should consider raising its location to above pool water level. Hi I have a variable speed ecostar and am now having the drive error, drive stalled. When it gets up to speed, the switch is supposed to release the capacitor. the motor makes humming sound but nothing happened, then the motor became burning hot. Is the GFCI test button tripped? Should I worry? If you program the incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. Hi Jason, I would wait to spend the money, until certain that would be the fix. Hi Tony, when all is good in the world, the pump basket will fill up full, and when a system is really air tight, you see no bubbles at all (through a clear pump lid), just solid water, filling the entire pump basket housing. Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? Recently when power came on it hums and shuts down after 6 seconds. After running almost 24 hours the pressure went upto 30 which is the maxium number on our filter gauge and the water circulation stopped. Or maybe the glue that Im assuming is no longer working? Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? power to my pool pump & timer quit working at the same time. Maybe not a pump issue, but supply issue. Signs of wear under the wear ring is normal, and it should be pumping normally. Additionally, ensure all o-rings, valves, and gaskets are lubricated and situated in the right positions. Open faced impellers need very large pliers, or a strap wrench, some have special tools to remove open brass impellers. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. A common mistake is to install the spring seal half backwards. When I went out to drain water from the pool it wouldnt turn on. Vacuum hose air leaks from splits in an old hose. Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? Thinking of switching to PentAir, I hear they are better built. Thanks. Hard for me to say if the motor is shot, but it has sure had a rough life! The wire size may depend on the distance of wire run. Your pressure should be much lower, maybe 5-10 psi, without the cartridge in place. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. Automatic reset is 60 minutes. Second thought is are the pipes plumbed into the valve correct? Running very smoothly and pumping very hard. If there isnt any apparent damage, keep reading. I just replaced a Hayward 2 hp SP2615X20 that started making a loud noise while still pumping, so I figured the bearings or something were gone, with a Hayward SP3015X20AZ 2 hp. If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. Check the motor vent holes, (bottom front) to be sure they are not clogged. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. Spray shaving cream around all of these areas and run pump with the vac connected, to see if you can see the cream being sucked in, in these areas. Pull out on the dial, and reset it, until you feel the gears engage. Hi Sal, for the pump lid, it may help to close the incoming and outgoing valves, and open the filter air bleeder, to release the suction. Troubleshooting a Salt Chlorinator First, check power. Could also be a clog in the pipe. Hi Leah, good question, and I understand. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Tough one, good luck! Theres a few ideas to check, good luck! But lack of sand should not cause a leaking problem. Usually OK with a 12 lift, but more than that can be a struggle. Third, is that breakers sometimes dont last forever, and can be go bad, usually after 20-30 yrs tho. Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. I turned the gas off to it. Shut off power at the breaker to all pool equipment Reprime the pump again, open water valves and test. If you like the Perflex filter, go with the Perflex EC75A, which is rated for 80 GPM, EC65A is only rated for 67 gpm. APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety Then you can pump out the water with a submersible pump, or depending on the surface material and design of your water feature, it may be better for the surfaces not to drain it, but to treat it with chemicals and put a heavy cover over it, where possible. The GFI doesnt break which is where the pump is plugged into, it is just the breaker on the eletrical box that pops. You can also call Hayward directly for tech support. On an Intermatic timer clock, there is a tab, at around 4 oclock on the dial, that is pushed to the left to turn off the timer, or override the timer settings. Ran fine as long as I didnt turn it off. If the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. Hi probably not related to the vacuuming, but sounds like a motor problem. Home; Events. Or maybe a clamp? There may be some stray voltage running around the system, on the bonding wire. We have a Hayward Swimpro Lx 1.0 hp and have a slow leak coming from underneath, maybe in between the housing and the motor. Had it running today at high rpm and totally turned off after about 20 minutes. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. It seems to be coming from the wet side of the pump the strainer housing. Is there a solution for this problem? Thanks. hopefully. I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. "url": "https://blog.intheswim.com/"
YOu can shim under a piece of rubber, or carpet, or cardboard which wont last long, but anything between the pump and the pad should quiet the pump, and take up space to prevent the vibration. Another possible cause is that the impeller is clogged with very small debris. Automatic reset is immediate after error is corrected. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. To determine the cause of your noisy pump, investigate the following reasons: Theres no need to feel overwhelmed if your Hayward pool pump isnt functioning correctly. The motor runs but does not Could this be true? Replacing it involves separating the wet end from the motor end, then holding the shaft so you can unthread the impeller, removing the two old seal halves, and replacing in the same direction or orientation to each other, rethreading on the impeller and reconnecting the seal plate to the pump housing. At75%, or lower, in either polarity, it's time to consider replacing the cell. Tried to vacuum. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. (GFI 240V 20amp) Hi Andy, breakers are not usually screwed down, they snap in place, you can try pushing firmly on the front of the breaker with fingers, to be sure it is seated properly. If its not the cord, I would suggest the filter, cleaning the fingers with a good soak to de-scale and de-grease. Backwashing or cleaning the pump basket is the usual fix. Hi Amy, the timer is usually wired between the pump and the breaker. We have a Hayward Aqua Plus system. My client just had his pool guy open his pool for the summer yesterday and they discovered voltage in the pool. A closed valve, or plugs in the pool wall? 1. I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. Hi check that the pump is not drawing air in, most common areas are around the pump lid, drain plugs and most common, the threaded pipe coming into the pump, which should be sealed with thread sealant like Teflon Tape and/or RTV silicone. After the pump and filter are fully drained, screw the plugs back in slightly to keep bugs out, but leave them loose so they will still drain, as needed. Breville Tamper Coffee Kit 54mm, We have a Hayward 1.5 lx. Look closely at the centrifugal switch in the middle/center/end of shaft, make sure its tight and intact. Yes, you can briefly test motors, for a few seconds without water, no problem. Hi Liane, a click coming from a control panel, could be a relay, clicking to send the signal to start the pump, but the signal is lost along the way. I changed the sand and it is still occurring. Hi Rachel, Im guessing a Hayward Perflex DE filter? Hi Frank, two possible reasons might be nighttime moisture (dew), or small insects, both contacting the circuit, on the timer or connected electrical outlet, and causing a brief short, which can trip the breaker. A warranty process with Hayward may take awhile, a few weeks this time of year I would think. In most cases, it means that your motor is on the way out. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. Flipped the breakers back on this morning after problem fixed. I tried replacing that oring and the leak got worse somehow and it just doesnt feel like there is any pressure when tightening the 6 bolts that hold the pump and motor together. Inspect the capacitor, at 9 oclock in the rear, for bulges, cracks or brown liquid. My pump & filter are Haywards. Probably a loose fitting, clamp or o-ring. Inspect wiring for any loose or corroded connections. First, in regard to my Hayward pump basket lid, it is hard to turn counter clockwise, when i need to remove it but it does turn. We have a Hayward ultra pro lx series pump for our above ground pool. Might be some voltage issues? Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera.
Traefik Tls Passthrough Example,
Engineering Job Outlook 2021,
Unlicensed Physician Jobs Florida,
Articles H